Forni a storta a pareti calde fino a 1100 ° C in idrogeno

If flammable process gases, such as hydrogen, are used, the retort furnace is also equipped with the required safety technology.  

Controllo dei processi

Funzione e attrezzatura

NRA300_09H2_fmt.jpeg

Hot-Wall Retort Furnaces for Thermal Debinding in Hydrogen (H2) and for Presintering 

If flammable process gases, such as hydrogen, are used, the retort furnace is also equipped with the required safety technology.  

  • Safety package for operation in hydrogen 
  • Flammable process gases with controlled overpressure of 10‑50 mbar relative 
  • PLC process control with safety monitoring (F-PLC) and graphic touch panel  
  • Redundant gas inlet valves for hydrogen 
  • Monitoring of all process gas input pressures 
  • Hydrogen sensor/hydrogen gas warning sensors in the furnace housing 
  • Bypass for safe purging of the furnace chamber with inert gas 
  • Torch for thermal post combustion of the exhaust gases
  • Protective gas emergency flood container for purging the furnace in case of malfunction 

Equipaggiamento aggiuntivo

  • Condensate trap (for IDB and H2 models), which is dependent on the quantity and condensation behavior of the type of binder that is used

Richiesta di offerta

Richiesta di offerta

CAPTCHA
Questa domanda è un test per verificare che tu sia un visitatore umano e per impedire inserimenti di spam automatici.

Centro prove per clienti

Quale forno rappresenta la soluzione giusta per questo processo specifico? Non è sempre facile trovare la risposta a questo interrogativo. Per questo motivo abbiamo allestito un grande e moderno centro tecnico in cui è a disposizione dei clienti una selezione rappresentativa dei nostri forni per poter effettuare delle prove.