Skrzynki gazowe i blokady gazowe do pieców komorowych NW 150 – NW 1000

Dla niepalnych gazów osłonowych i reakcyjnych, jak argon, azot i gaz formierski (przestrzegać przepisów krajowych).

Funkcja i wyposażenie

NW200.jpg
Begasungsglocke.jpg
Begasungssysteme2.jpg

Protective Gas Boxes

These protective gas boxes have a cover with a sealing profile as well as a protective gas inlet and outlet. They are pulled out of the furnace in cold condition and charged from above.

  • Tmax 1100 °C
  • For non-combustible protective and reactive gases argon, nitrogen and forming gas (observe national regulations)
  • Protective gas box with fiber seal and cover with locks, inert gas introduction via a pipe into the bottom of the box
  • Protective gas connection via quick coupling with hose connector (inner diameter 9 mm)
  • Piping for gas inlet and outlet through the furnace collar
  • Forklift receptive
  • Heat-resistant alloy 314 (AISI)/(DIN material no. 1.4841)
  • Charge thermocouple type K for temperature display or charge control

Protective Gas Hoods

Protective gas hoods consist of a and a bottom with a sealing profile as well as protective gas inlet and outlet. After charging the bottom in front of the oven in cold condition, the hood is put on and the drawer or the car is pushed back into the oven.

Design as protective gas boxes, but

  • Gassing hood with eye for raising the hood by crane
  • Hood bottom with sealing
  • Piping for gas inlet and outlet at the hood through the furnace collar

Dodatkowe wyposażenie

Additional equipment for protective gas boxes and hoods

  • Digital temperature display
  • Gas supply systems

Specyfikacja techniczna

Furnace Article no. Inner dimensions in mm   Article no. Inner dimensions in mm Charging
  Protective gas box w d h   Protective gas hood w d h the furnace
NW 150 631001329 330 420 400   631001334 300 360 400 Drawer
NW 200 631001330 400 420 500   631001335 370 360 450 Drawer
NW 300 631001331 450 550 550   631001336 420 530 500 Drawer
NW 440 631001332 500 600 750   631001337 470 580 550 On a bogie
NW 660 631001333 500 750 750   631001338 470 750 550 On a bogie
NW 1000 on request   on request On a bogie
Article no. 601655055, 1 set of fiber insulation cord, 5 strips of 610 mm each
Work space = box inner dimensions: - 30 mm to all sides
Larger boxes and custom dimensions available upon request