Retort Furnace Cooling Systems

Optional cooling systems are available for our retort furnaces for fast cooling of the batches.

Function and equipment

Schema_Gasschnellkuehl.jpg
Geblaesekuehlung.jpg
Gasschnellkuehlung.jpg

Indirect cooling (hot-wall retort furnaces)

  • Ambient air is blown onto the outer retorte surface to cool it down. The waste heat is removed via the exhaust air outlet of the furnace.
  • The charge is cooled indirectly, which means that the atmosphere in the retort is not affected by the cooling
  • The charge cannot be quenched with the cooling system

Direct cooling (cold-wall and hot-wall retort furnaces) 

  • Rapid gas cooling in the retort. For this purpose, the furnace atmosphere is circulated through a heat exchanger.
  • The system pressure is not increased by the cooling; there is no gas quenching at high pressure
  • Not available for processes with flammable furnace atmospheres

Request for quotation

Anfrage

CAPTCHA

Customer Test Center

What furnace is the right choice for this specific process? This question cannot always be answered easily. Therefore, we have set up our modern test center which is unique in respect to size and variety. A representative number of furnaces is available for tests for our customers.