Function and equipment
Protective gas box with evacuation lid according to AMS2750G
These boxes are based on the standard protective gas boxes for furnaces with hinged door. To fulfill AMS2750G, instrumentation, type D requirements the boxes are equipped with necessary measuring ports.
- Temperature uniformity class 2: +/- 5 °C in useful space
- Additional port for customers flexible SAT thermocouple with max. 1,5 mm diameter
- Thermcouple, overtemperature protection, metal clad thermocouple, type N with plug
Technical specifications
Article no. | Furnace | Inner dimensions in mm | Outer dimensions in mm1 | |||||
---|---|---|---|---|---|---|---|---|
(Furnace with swinging door) | (Furnace with lift door) | w | d | h | W | D | H | |
631001021 | 631001026 | NA 60/.. | 270 | 420 | 260 | 336 | 460 | 340 |
631001022 | 631001027 | NA 120/.. | 350 | 520 | 340 | 436 | 560 | 430 |
631001023 | 631001028 | NA 250/.. | 480 | 630 | 460 | 546 | 680 | 600 |
631001024 | 631001029 | NA 500/.. | 630 | 780 | 610 | 696 | 836 | 760 |
Article no. 601655055, 1 set of fiber insulation cord, 5 strips of 610 mm each Work space = box inner dimensions: - 30 mm to all sides Larger boxes and custom dimensions available upon request 1Without piping |