Function and equipment
These boxes are based on the standard protective gas boxes for furnaces with hinged door. To fulfill AMS2750G, instrumentation, type D requirements the boxes are equipped with necessary measuring ports.
- Temperature uniformity class 2: +/- 5 °C in useful space
- Additional port for customers flexible SAT thermocouple with max. 1,5 mm diameter
- Thermcouple, overtemperature protection, metal clad thermocouple, type N with plug
Technical specifications
Article no. | Furnace | Inner dimensions in mm | Outer dimensions in mm1 | |||||
---|---|---|---|---|---|---|---|---|
(Furnace with swinging door) | (Furnace with lift door) | w | d | h | W | D | H | |
631001021 | 631001026 | NA 60/.. | 270 | 420 | 260 | 336 | 460 | 340 |
631001022 | 631001027 | NA 120/.. | 350 | 520 | 340 | 436 | 560 | 430 |
631001023 | 631001028 | NA 250/.. | 480 | 630 | 460 | 546 | 680 | 600 |
631001024 | 631001029 | NA 500/.. | 630 | 780 | 610 | 696 | 836 | 760 |
Article no. 601655055, 1 set of fiber insulation cord, 5 strips of 610 mm each Work space = box inner dimensions: - 30 mm to all sides Larger boxes and custom dimensions available upon request 1Without piping |