Piece komorowe z obiegiem powietrza o pojemności powyżej 1000 l z systemami zabezpieczeń

Nadają się do suszenia ciężkiego wsadu o dużych wymiarach zawierającego rozpuszczalniki zgodnie z EN 1539.

Sterowanie procesami

Funkcja i wyposażenie

N5600_45HAS.png
Frischluftfilter_NA5600_45LS.png
NA2000_45LS.png
KTR_Einfahrspuren

Models  N ../45 ..  are equipped with the corresponding safety technology for drying larger and heavier charges containing solvent. As with the smaller models, the furnaces in this range can be adapted with selected additional equipment to suit the respective charge and process.

  • Furnace technology based on forced convection chamber furnaces
  • For a description of the safety technology, refer to models NA 120/45 LS ff.
  • Over-temperature limiter with manual reset as over-temperature protection for the furnace and the charge
  • Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
  • Defined application within the constraints of the operating instructions
  • Controller with touch operation P570 (50 programs with each 40 segments)
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
  • Freeware NTEdit for convenient program input via ExcelTM for WindowsTM on the PC
  • Freeware NTGraph for evaluation and documention of firings using ExcelTM for WindowsTM on the PC
  • MyNabertherm App for online monitoring of the firing on mobile devices for free download

Dodatkowe wyposażenie

  • EN 1539 with reduced exhaust air flow rate to 25 % after the main evaporation time to save energy
  • EN 1539 with temporary switching off for processes in which no flammable substances are released
  • Process control and documentation via VCD software package for monitoring, documentation and control

Specyfikacja techniczna

ModelTmaxInner dimensions in mmOuter dimensions2 in mmHeating powerExhaust air flow rateMaximum volume of solvent in g at temperature:
 °CwdhWDHin kW1in m3/h75 °C100 °C125 °C150 °C200 °C250 °C300 °C350 °C400 °C450 °C
NA 1000/45 LS45010001000100020152150237548200123886652332622151311
NA 1500/45 LS45010001500100020152650237548200136987559383126181514
NA 1500/45B LS45015001000100025152150237548200136987559383126181514
NA 2000/45 LS450110015001200211526502575722501721259575493933232018
NA 2000/45B LS450150011001200251522502575722501721259575493933232018
NA 2010/45 LS450100010002000201522003375722501771289878514134242118
NA 2880/45 LS4501200120020002215240033758425019714511290604941292522
NA 4000/45 LS45015002200120025153350257584400291212163129856958403531
NA 4000/45B LS45022001500120033152650257584400289211162128846857393531
NA 4010/45 LS45010002000200020153200337584400298218168133887260423733
NA 4010/45B LS45020001000200030152200337584400296216166132877159413632
NA 4500/45 LS45015001500200025502750337584400307225174138927563443834
NA 7200/45 LS45020001500240030502750387014450041030423618912610488615448
1Depending on the furnace design, connected load might be higher
2External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.

Zapytanie ofertowe

Zapytanie ofertowe

CAPTCHA
To pytanie sprawdza czy jesteś człowiekiem i zapobiega wysyłaniu spamu.