Piece retortowe szybowe do 1100 °C

Piece retortowe nagrzewane przez ściany są ładowane od góry za pomocą dźwigu lub innego urządzenia do podnoszenia klienta.

Sterowanie procesami

Funkcja i wyposażenie

SRA300_06.jpg
SRA200_09.jpg
Strukturblech.jpg

The retort furnaces SR and SRA (with gas circulation) are designed for operation under non-flammable or flammable protective or reaction gases. The hot-wall retort furnaces are loaded from above by crane or other lifting equipment provided by the customer. In this way, even large charge weights can be loaded into the furnace chamber.

Depending on the temperature range in which the furnace be used, the following models are available:

Models SRA ../06 with Tmax 650 °C

  • Heating inside the retort
  • Gas-circulation with powerful fan in the furnace lid
  • Temperature uniformity up to +/- 5 °C inside the work space
  • Single-zone control
  • Retort made of 1.4571
  • Insulation made of high-grade mineral wool

Models SRA ../09 with Tmax 900 °C

  • Design like models SR…/06 with following differences:
    • All-around heating from outside of the retort
    • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
    • Retort made of 1.4828

Models SR .../11 with Tmax 1100 °C

  • Design like models SR…/09 with following differences:
    • Without gas-circulation
    • Top down multi-zone control of the furnace heating
    • Retort made of 1.4841

Standard Equipment (all models)

  • Design like standard equipment of models NR and NRA with following differences: see control alternative page 71
    • Compact housing in frame construction with inserted stainless steel sheets
    • Charging from above with crane or other lifting equipment from customer
    • Hinged lid with opening to the side
    • Welded charging frame resp. gas-guiding box for furnaces with circulation
    • Gas-supply system for one non-flammable protective or reactive gas with flowmeter and magnetic valve
    • Furnace temperature control
    • Possible connection of an optional vacuum pump (for cold evacuation or for processes up to 600 °C under vacuum)
    • Defined application within the constraints of the operating instructions
    • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive

Additional equipment, H2 version or IDB version see models NR and NRA

Specyfikacja techniczna

Model

Tmax

Inner dimensions of alloy retort

Volume

Outer dimensions1 in mm

Electrical

Weight

 

°C

Ø in mm

h in mm

in l

W

D

H

connection*

in kg

SR(A) 90..

650,

400

750

90

1400

2100

2600

3-phase

1600

SR(A) 220/..

900

600

1000

220

1600

2300

2700

3-phase

2200

SR(A) 460/..

or

700

1200

460

1800

2600

3200

3-phase

4000

SR(A) 850/..

1100

900

1350

850

2100

2900

3500

3-phase

4800

SR(A) 1400/..

 

1100

1500

1400

2400

3300

3800

3-phase

7000

1External dimensions vary when furnace is equipped with additional equipment. Dimensions on requwwest. 


 