Высокотемпературные печи с нагревом из дисилицида молибдена с волокнистой изоляцией до 1800 °C

Стандартные компактные модели подходят для плавления небольших опытных партий стекла, для кварцевого стекла или стеклокерамики, где требуются высокие рабочие температуры и важна высокая точность. 

Управление процессами

Функции и оборудование

HT29_17.png
HT450_16.png
HT160_17_.png
HT64_16S.png
HT64_17DB100-2
HT_Begasungssystem.png
Zweituerausfuehrung.jpg
HT160Boden
HT_Schaulöcher_heiss_kalt.jpg

With their solid construction, these high-temperature furnaces fulfill the demands of everyday work in laboratories and production. The compact standard models are suitable for melting small quantities of glass samples, for quartz glass or glass-ceramic application where high working temperatures are required and high levels of precision are needed. The very good temperature uniformity and practical details set very high quality benchmarks and are the optimum solution for many applications. The furnaces can be extended with extra features from our extensive range to suit specific processes. 

  • Tmax 1600 °C, 1750 °C, or 1800 °C
  • Recommended maximum working temperature approx. 50 °C below Tmax of the furnace. Higher working temperatures will increase wear and tear.
  • Dual shell ventilated housing made of textured stainless steel sheets for low surface temperature and high stability
  • Heating from both sides via molybdenum disilicide heating elements
  • High-quality fiber insulation backed by special insulation
  • Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
  • Long-life roof insulation with special suspension
  • Temperature uniformity at 1450 °C up to +/− 6 °C according to DIN 17052-1
  • Chain-guided parallel swivel door for precise opening and closing of the door
  • Two-door design (front/back) for high-temperature furnaces from HT 276/..
  • Labyrinth sealing ensures the least possible temperature loss in the door area
  • Reinforced floor as protection for bottom insulation as standard from models HT 16/16 upwards (distributed load 5 kg/dm2)
  • Vapor vent in the furnace roof with motorized exhaust air flap, controlled via the extra function of the controller
  • Stainless steel exhaust hood as interface to customer’s exhaust system
  • Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
  • Defined application within the constraints of the operating instructions
  • Controller with touch operation P570 (50 programs with each 40 segments)

Дополнительное оборудование

  • Cooling system to cool the furnace with a defined temperature gradient or with a preset fresh air volume. Both operating modes can be switched on and off for different segments by means of the extra function of the controller.
  • Thermocouple inlet with screw cap
  • Thermocouple for the heating control with calibration certificate
  • Protective gas connection to purge with non-flammable process gases (not completely gas-tight)
  • Automatic gas supply system with solenoid valve and rotameter, controlled by the extra function of the controller
  • Refractory brick floor insulation for a higher floor load (Tmax 1700 °C)
  • Lift door
  • Automatic door lock incl. door contact switch
  • Heating elements protected against mechanical damage
  • Special heating element qualities e. g. for zircon oxide applications
  • Ethernet interface

Спецификации

ModelTmaxInner dimensions in mmVolumeOuter dimensions1 in mmConnectedElectricalWeight
 °Cwdhin lWDHload in kWconnectionin kg
HT 08/161600150300150874064017558.53-phase2215
HT 16/16160020030026016820690186012.53-phase2300
HT 29/1616002753003502998574019909.83-phase2350
HT 40/161600300350350401010800199012.53-phase420
HT 64/161600400400400641140890204018.53-phase555
HT 128/16160040080040012811401280204026.53-phase820
HT 160/16160050055055016012501040226021.53-phase760
HT 276/161600500100055027613401600229043.53-phase1270
HT 450/161600500115078045013801820257065.03-phase1570
            
HT 08/171750150300150874064017558.53-phase2215
HT 16/17175020030026016820690186012.53-phase2300
HT 29/1717502753003502998574019909.83-phase2350
HT 40/171750300350350401010800199012.53-phase420
HT 64/171750400400400641140890204018.53-phase555
HT 128/17175040080040012811401280204026.53-phase820
HT 160/17175050055055016012501040226021.53-phase760
HT 276/171750500100055027613401600229043.53-phase1270
HT 450/171750500115078045013801820257065.03-phase1570
            
HT 08/181800150300150874064017558.53-phase2215
HT 16/18180020030026016820690186012.53-phase2300
HT 29/1818002753003502998574019909.83-phase2350
HT 40/181800300350350401010800199012.53-phase420
HT 64/181800400400400641140890204018.53-phase555
HT 128/18180040080040012811401280204026.53-phase820
HT 160/18180050055055016012501040226021.53-phase760
HT 276/181800500100055027613401600229043.53-phase1270
HT 450/181800500115078045013801820257065.03-phase1570
1External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.
2Heating only between two phases

Запрос коммерческого предложения

Запрос коммерческого предложения

CAPTCHA
Этот вопрос задается для того, чтобы выяснить, являетесь ли Вы человеком или представляете из себя автоматическую спам-рассылку.