Protective Gas Boxes According to AMS2750H, Instrumentation Type D for Forced Convection Furnaces

Additional port for customers flexible SAT thermocouple with max. 1,5 mm diameter.

Function and equipment

Begasungskasten_Eva_AMS.jpg

These boxes are based on the standard protective gas boxes for furnaces with hinged door. To fulfill AMS2750H, instrumentation, type D requirements the boxes are equipped with necessary measuring ports.

  • Temperature uniformity class 2: +/- 5 °C in useful space
  • Additional port for customers flexible SAT thermocouple with max. 1,5 mm diameter
  • Thermcouple, overtemperature protection, metal clad thermocouple, type N with plug

Technical specifications

Article no.

 

Furnace

Inner dimensions in mm

Outer dimensions in mm1

(Furnace with swinging door)

(Furnace with lift door)

 

w

d

h

W

D

H

631001021

631001026

NA 60/..

270

420

260

336

460

340

631001022

631001027

NA 120/..

350

520

340

436

560

430

631001023

631001028

NA 250/..

480

630

460

546

680

600

631001024

631001029

NA 500/..

630

780

610

696

836

760

Article no. 601655055, 1 set of fiber insulation cord, 5 strips of 610 mm each
Work space = box inner dimensions: - 30 mm to all sides
Larger boxes and custom dimensions available upon request
1Without piping

Request for quotation

Anfrage

For detailed information on how we handle user data, please see our Privacy Policy.