Suszarki komorowe z systemami zabezpieczeń

Nadają się do wielu procesów obróbki cieplnej wsadu zawierającego rozpuszczalniki zgodnie z EN 1539.

Sterowanie procesami

Funkcja i wyposażenie

KTR4500LS_.png
KTR3100DT.png
Einfahrrampen
KTR1500 mit Chargierwagen.png
KTR1500_ausziehbarer_Einlegeboegen.png

The safety technology integrated in chamber ovens in the KTR .. LS range makes them suitable for many processes where flammable substance evaporate from the charge. 

Sensitive products, such as some silicones, require constant, gentle movement of the charge during heat treatment. The ovens can be equipped with wire frame boxes designed to suit the rotary mechanism.

  • Furnace technology based on chamber ovens
  • For a description of the safety technology refer to models NA 120/45 LS ff.
  • Over-temperature limiter with manual reset as over-temperature protection for the furnace and the charge
  • Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
  • Defined application within the constraints of the operating instructions
  • Controller with touch operation P570 (50 programs with each 40 segments)
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
  • Freeware NTEdit for convenient program input via ExcelTM for WindowsTM on the PC
  • Freeware NTGraph for evaluation and documentation of firings using ExcelTM for WindowsTM on the PC
  • MyNabertherm App for online monitoring of the firing on mobile devices for free download

Dodatkowe wyposażenie

  • Fresh-air filter
  • Air circulation filter for the internal air
  • Drive-in tracks
  • Charging cart
  • Customer-specific rotary rack
  • Process control and documentation via VCD software package for monitoring, documentation and control

Specyfikacja techniczna

ModelTmaxInner dimensions in mmVolumeOuter dimensions2 in mmHeating powerExhaust air volumetric flow rateMaximum volume of solvent in g at
temperature:
 °Cwdhin lWDHin kW1in Bm3/h50 °C100 °C150 °C200 °C250 °C260 °C
KTR 1000 LS26010001000100010001900143023153639032514177524139
KTR 1500 LS26010001000150015001900143028153639034215388584644
KTR 3100 LS260125012502000310021501680345545520492227134907269
KTR 4500 LS2601500150020004500240019303455545205362561551068582
KTR 6125 LS260175017502000612526502200360063750757359216147118114
KTR 8000 LS260200020002000800029002450360081950963457275187151145
1Depending on the furnace design, connected load might be higher
2External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.