Heating Cabinets electrically heated
They are heated with a separate heating unit that is generally located behind the heating cabinet.
They are heated with a separate heating unit that is generally located behind the heating cabinet.
Heating cabinets are ideal for processes in the low temperature range up to max. 150 °C, such as for drying, preheating molds and tools or tempering and curing plastics. They have a compact design and are especially suitable for large charges. They are heated with a separate heating unit that is generally located behind the heating cabinet.
Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions1 in mm | Heating power | Connected load | ||||
|---|---|---|---|---|---|---|---|---|---|---|
°C | b | d | h | in l | W | D | H | in kW | in kW | |
WK 4500 | 150 | 1500 | 1500 | 2000 | 4500 | 1980 | 3110 | 2500 | 18 | 21 |
WK 6000 | 150 | 1500 | 2000 | 2000 | 6000 | 1980 | 3610 | 2500 | 18 | 21 |
WK 6001 | 150 | 2000 | 1500 | 2000 | 6000 | 2480 | 3110 | 2500 | 18 | 21 |
WK 7500 | 150 | 2500 | 1500 | 2000 | 7500 | 2980 | 3110 | 2500 | 27 | 30 |
WK 8000 | 150 | 2000 | 2000 | 2000 | 8000 | 2460 | 3570 | 2500 | 27 | 32 |
WK 10000 | 150 | 2000 | 2500 | 2000 | 10000 | 2460 | 4070 | 2500 | 45 | 50 |
WK 10001 | 150 | 2500 | 2000 | 2000 | 10000 | 2960 | 3570 | 2500 | 45 | 50 |
WK 12000 | 150 | 2000 | 3000 | 2000 | 12000 | 2460 | 4570 | 2500 | 45 | 50 |
WK 15000 | 150 | 2500 | 3000 | 2000 | 15000 | 2900 | 4720 | 2500 | 54 | 62 |
WK 17500 | 150 | 2500 | 3500 | 2000 | 17500 | 2900 | 5220 | 2500 | 54 | 62 |
1External dimensions vary when furnace is equipped with additional equipment. Dimensions on request | ||||||||||
A complete overview of our extensive range of furnaces and plants that are used for heat treatment processes in air can be found in our catalog "Thermal Process Technology 1, furnaces and heat treatment plants for processes under air".