Salt-Bath Furnaces for Chemical Hardening of Glass

Tmax 500 °C, tailored design possible up to Tmax 1000 °C.

Process Control

Function and equipment

TS8_50.png
Chargierkorb.png
TWB.png
Salzbadtiegel.png

Salt-bath furnace TS ../50 is designed especially for chemical tempering of glass in the laboratory. Chemical tempering is a process used to strengthen thin glass with wall thicknesses of just a few millimeters. The benefit of chemical pre-stressing is that the surface quality remains intact. Almost all glass with a high sodium content can be strengthened through ion exchange.

  • Tmax 500 °C
  • Salt-bath furnace in compact design with salt-bath and pre-heated-/cooling chamber above the salt-bath
  • Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
  • Bath temperature control
  • Indirect heating of the preheated chamber from the salt-bath
  • Automatic, time controlled movement from the preheating chamber into the salt-bath and back
  • Electrical door lock
  • Crucible made of hiqh-quality CrNi steel
  • Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load
  • Defined application within the constraints of the operating instructions
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
  • Controller with touch operation P570 (50 programs with each 40 segments)

Additional equipment

  • Hood for connection to local exhaust system
  • Charging basket according to customers drawing
  • Active heating for the preheated chamber
  • PLC
  • Process control and documentation via Nabertherm Control Center (NCC) for monitoring, documentation and control

Technical specifications

ModelTmaxInner dimensions crucible in mmVolumeOuter dimensions2 in mmHeating powerElectricalWeight
 °C1wdhin lWDHin kW3connection*in kg
TS 8/5050030010010081600105024002.03-phase650
TS 90/505006503004509016001050240020.03-phase700
1Salt-bath temperature
2External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.
3Depending on furnace design connected load might be higher 

Request for quotation

Anfrage

For detailed information on how we handle user data, please see our Privacy Policy.