Protective Gas Boxes with Evacuation Lid According to AMS2750G, Instrumentation type D
Before the box is placed in the furnace, in a cold state an evacuation and protective gas atmosphere are alternately generated to force out the oxygen and achieve a pure atmosphere.
Function and equipment
These boxes are based on the standard protective gas boxes with evacuation lid for furnaces with hinged door. Before the box is placed in the furnace, in a cold state an evacuation and protective gas atmosphere are alternately generated to force out the oxygen and achieve a pure atmosphere.
- Temperature uniformity class 2: +/- 5 °C in useful space
- Additional port for customers flexible SAT thermocouple with max. 1,5 mm diameter
- Thermcouple, overtemperature protection, metal clad thermocouple, type N with plug
Technical specifications
Article no. | Furnace | Inner dimensions in mm | Outer dimensions in mm1 | |||||
---|---|---|---|---|---|---|---|---|
(Furnace with hinged door) | (Furnace with lift door) | w | d | h | W | D | H | |
631001052 | 631001057 | NA 60/.. | 230 | 380 | 220 | 318 | 468 | 297 |
631001053 | 631001056 | NA 120/.. | 330 | 480 | 320 | 418 | 568 | 412 |
631001054 | 631001055 | NA 250/.. | 430 | 580 | 370 | 518 | 668 | 532 |
631001049 | 631001054 | NA 500/.. | 560 | 810 | 530 | 648 | 898 | 692 |
Article no. 601655055, 1 set of fiber insulation cord, 5 strips of 610 mm each Work space = box inner dimensions: - 30 mm to all sides Larger boxes and custom dimensions available upon request 1Without piping |