Protective Gas Boxes with Evacuation Lid According to AMS2750G, Instrumentation type D

Before the box is placed in the furnace, in a cold state an evacuation and protective gas atmosphere are alternately generated to force out the oxygen and achieve a pure atmosphere.

Function and equipment

Begasungskasten_Eva_AMS.jpg

These boxes are based on the standard protective gas boxes with evacuation lid for furnaces with hinged door. Before the box is placed in the furnace, in a cold state an evacuation and protective gas atmosphere are alternately generated to force out the oxygen and achieve a pure atmosphere.

  • Temperature uniformity class 2: +/- 5 °C in useful space
  • Additional port for customers flexible SAT thermocouple with max. 1,5 mm diameter
  • Thermcouple, overtemperature protection, metal clad thermocouple, type N with plug

Technical specifications

Article no.   Furnace Inner dimensions in mm Outer dimensions in mm1
(Furnace with hinged door) (Furnace with lift door)   w d h W D H
631001052 631001057 NA 60/.. 230 380 220 318 468 297
631001053 631001056 NA 120/.. 330 480 320 418 568 412
631001054 631001055 NA 250/.. 430 580 370 518 668 532
631001049 631001054 NA 500/.. 560 810 530 648 898 692
Article no. 601655055, 1 set of fiber insulation cord, 5 strips of 610 mm each
Work space = box inner dimensions: - 30 mm to all sides
Larger boxes and custom dimensions available upon request
1Without piping