Protective Gas Boxes for Models SAL 30/45 - SAL 500/85

Due to weight reasons we recommend to use a charging aid for charging.

Function and equipment

Begasungskasten_S30.jpg

For tempering and bright annealing, workpieces are laid in the box, the lid is pressed firmly shut using the sealing locks and flushed with protective gas outside the box for some time and then placed in the furnace. Due to weight reasons we recommend to use a charging aid for charging.

  • For non-combustible protective and reactive gases argon, nitrogen and forming gas (observe national regulations)
  • Protective gas box with fiber seal and cover with locks, inert gas introduction via a pipe into the bottom of the box
  • Protective gas connection via quick coupling with hose connector (inner diameter 9 mm)
  • Piping for gas inlet and outlet through the furnace collar
  • Heat-resistant alloy: 450 °C - 304 (AISI)/(DIN material no. 1.4301), 650 °C - 321 (AISI)/(DIN material no. 1.4541) or 850 °C - 309 (AISI)/(DIN material no. 1.4828)
  • Charging aid lifting eyes
  • Charge thermocouple type K for temperature display or charge control

Additional equipment

Additional equipment

  • Digital temperature display
  • Gas supply systems

Technical specifications

Article no. with charge Furnace Inner dimensions in mm Outer dimensions in mm1
thermocouple   w d h W D H
631000500 SAL 30/45 215 165 277 281 231 354
631000501 SAL 60/45 265 265 377 331 331 454
631000502 SAL 120/45 365 365 477 431 431 554
631000503 SAL 250/45 515 515 627 581 561 704
631000504 SAL 500/45 665 665 727 731 731 804
631000505 SAL 30/65 215 165 277 281 231 354
631000506 SAL 60/65 265 265 377 331 331 454
631000507 SAL 120/65 365 365 477 431 431 704
631000508 SAL 250/65 515 515 627 581 561 654
631000509 SAL 500/65 665 665 727 731 731 804
631000510 SAL 30/85 215 165 277 281 231 354
631000511 SAL 60/85 265 265 377 331 331 454
631000512 SAL 120/85 365 365 477 431 431 554
631000513 SAL 250/85 515 515 627 581 561 704
631000514 SAL 500/85 665 665 727 731 731 804
Article no. 601655055, 1 sales unit of fiber insulation cord, 5 strips of 610 mm each1 Without piping

Request for quotation