Protective Gas Boxes According to AMS2750G, Instrumentation Type D for Forced Convection Furnaces

Additional port for customers flexible SAT thermocouple with max. 1,5 mm diameter.

Function and equipment

Begasungskasten_Eva_AMS.jpg

These boxes are based on the standard protective gas boxes for furnaces with hinged door. To fulfill AMS2750G, instrumentation, type D requirements the boxes are equipped with necessary measuring ports.

  • Temperature uniformity class 2: +/- 5 °C in useful space
  • Additional port for customers flexible SAT thermocouple with max. 1,5 mm diameter
  • Thermcouple, overtemperature protection, metal clad thermocouple, type N with plug

Technical specifications

Article no.   Furnace Inner dimensions in mm Outer dimensions in mm1
(Furnace with swinging door) (Furnace with lift door)   w d h W D H
631001021 631001026 NA 60/.. 270 420 260 336 460 340
631001022 631001027 NA 120/.. 350 520 340 436 560 430
631001023 631001028 NA 250/.. 480 630 460 546 680 600
631001024 631001029 NA 500/.. 630 780 610 696 836 760
Article no. 601655055, 1 set of fiber insulation cord, 5 strips of 610 mm each
Work space = box inner dimensions: - 30 mm to all sides
Larger boxes and custom dimensions available upon request
1Without piping

Request for quotation

Anfrage