Protective Gas Boxes with Evacuation Lid According to AMS2750H, Instrumentation type D

Before the box is placed in the furnace, in a cold state an evacuation and protective gas atmosphere are alternately generated to force out the oxygen and achieve a pure atmosphere.

Function and equipment

Begasungskasten_Eva_AMS.jpg

These boxes are based on the standard protective gas boxes with evacuation lid for furnaces with hinged door. Before the box is placed in the furnace, in a cold state an evacuation and protective gas atmosphere are alternately generated to force out the oxygen and achieve a pure atmosphere.

  • Temperature uniformity class 2: +/- 5 °C in useful space
  • Additional port for customers flexible SAT thermocouple with max. 1,5 mm diameter
  • Thermcouple, overtemperature protection, metal clad thermocouple, type N with plug

Technical specifications

Article no.

 

Furnace

Inner dimensions in mm

Outer dimensions in mm1

(Furnace with hinged door)

(Furnace with lift door)

 

w

d

h

W

D

H

631001052

631001057

NA 60/..

230

380

220

318

468

297

631001053

631001056

NA 120/..

330

480

320

418

568

412

631001054

631001055

NA 250/..

430

580

370

518

668

532

631001049

631001054

NA 500/..

560

810

530

648

898

692

Article no. 601655055, 1 set of fiber insulation cord, 5 strips of 610 mm each
Work space = box inner dimensions: - 30 mm to all sides
Larger boxes and custom dimensions available upon request
1Without piping

Request for quotation

Anfrage