Forced Convection Chamber Furnaces up to 500 Liter Safety Technology

Suitable for charges containing solvents according to EN 1539.

Process Control

Function and equipment

NA120_45LS.png
N560_26HACLS.png
Zuluftoeffnung
Innenraum_NA120_45DB.png

Due to their very good temperature uniformity, these chamber furnaces with air circulation are especially suitable for processes such as drying paints or components with residues of flammable cleaning agents or the evaporation of solvents bound in the components.

  • Design based on forced convection chamber furnaces
  • High-powered heating to maintain the required air exchange rates
  • Powerful exhaust air fan to ensure underpressure in the furnace
  • Defined and monitored air circulation and exhaust air
  • Visual and audible malfunction signals
  • Over-temperature limiter with manual reset as over-temperature protection for the furnace and the charge
  • Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
  • Defined application within the constraints of the operating instructions
  • Controller with touch operation P570 (50 programs with each 40 segments)
  • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
  • Freeware NTEdit for convenient program input via ExcelTM for WindowsTM on the PC
  • Freeware NTGraph for evaluation and documention of firings using ExcelTM for WindowsTM on the PC
  • MyNabertherm App for online monitoring of the firing on mobile devices for free download

Additional equipment

  • EN 1539 with reduced exhaust air flow rate to 25 % after the main evaporation time to save energy
  • EN 1539 with temporary switching off for processes in which no flammable substances are released
  • Process control and documentation via VCD software package for monitoring, documentation and control

Technical specifications

Model

Tmax

Inner dimensions in mm

Volume

Outer dimensions1 in mm

Heating power

Exhaust air flow rate

Maximum volume of solvent in g
at temperature:

 

in °C

w

d

h

in l

W

D

H

in kW2

in m3/h

75 °C

150 °C

250 °C

350 °C

450 °C

NA 120/45 LS

450

450

600

450

120

1250

1550

1950

18

100 - 120

51

20

9

5

4

NA 250/45 LS

450

600

750

600

250

1350

1650

2080

24

100 - 120

93

36

17

9

7

NA 500/45 LS

450

750

1000

750

500

1550

1900

2220

24

100 - 120

104

42

21

12

9

1External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.